Compucentricity control

The Compucentricity package provides the functionality for compucentric tilting of the beta tilt axis. The Compucentricity package thereby minimizes the sideways movement of the image when the beta tilt is  changed.    

Compatible with: Tecnai and Titan family

Loading...

 

  • Eliminates by software the fact the tilt is not eucentric
  • Easy tilting due correction of non-eucentricity
  • Easy-to-use
  • Can be used for double-tilt holder calibration
  • Fully embedded in User interface
  • Reliable

Compucentricity Datasheet [PDF]

Loading...

 

  • Compucentricity consists of software for the compucentricity calculations and holder calibration procedure. Its use is through the regular microscope user interface goniometer control or through additional software packages such as k-Space Control and Smart Tilt.
  • When applied to a calibrated double-tilt holder, the image movements resulting from (even large) changes in beta-tilt angle can be reduced to values as small as 1 to 2 micrometers whereas real displacements that can amount up to several hundreds of micrometers on the X and Z axes.
  • The beta tilt axis of the any double-tilt holder is non-eucentric because there is not enough space between the objective-lens pole pieces to construct a second eucentric tilt (beta-tilt eucentricity would require changing the height of the beta tilt axis relative to the alpha tilt). The behavior of the non-eucentric beta tilt is, however, predicable when the location of the beta tilt axis is known. By deriving the latter from a calibration procedure, corrections can be applied to the other stage axes (predominantly X and Z) to compensate for the non-eucentric motion. The accuracy of the compensation strongly depends on the accuracy of specimen-position measurement. The effective compensation accuracy is of the order of 1 to 2 micrometers, independent of the actual change in beta tilt applied. Since manual beta tilting is typically done slowly, the compucentric corrections would be worse than any typical image movement during manual tilting. Compucentric corrections are therefore only used when (larger) software-controlled changes in beta tilt are applied.
  • Compucentric tilting is, of course, possible only on a goniometer where all five stage axes are under software control (i.e. the CompuStage).

 

Installation by Field Service Engineer:
Yes
Fit:
Embedded
Works With Tools:
Tecnai and Titan family
Availability:
2 months after receipt order
Dimensions:
Shipping Weight:
Origin:
The Netherlands
Air Transportation Packaging:
Yes
Estimated Installation Duration:
1 day
(Warranty included as standard. Product availability is subject to change without notice and all offers are subject to an authorized quotation.)
Loading...
no videos available at this time

Additional Recommended Items:

K-space Control

K-space Control

k-Space (or reciprocal space) is our view of diffraction space. k-Space itself and its manipulations to orient crystals can be difficult to handle. k-Space Control is a program designed to make working in diffraction considerably easier.
Smart Tilt control

Smart Tilt control

Smart Tilt gives assistance to the user in tilting with a double-tilt specimen holder of the CompuStage.
Tecnai Microscope Control Upgrade - Version 4.0

Tecnai Microscope Control Upgrade - Version 4.0

Microscope control upgrade contains hardware and software that enhances the ease of operation with embedded application software, ensures the full benefit of your systems' leading edge performance and also prepares your instrument for future developments.
CompuStage Low-Background, Double-Tilt Specimen Holder

CompuStage Low-Background, Double-Tilt Specimen Holder

Double tilt TEM specimen holder ideal for combination with EDX.