Contact Us Locations Welcome to FEI [ Register ] [ ]
Loading...

Versa™ 3D

Versa 3D High Vacuum
Building on the history and success of FEI's pioneering DualBeam, low vacuum and ESEM™ expertise, FEI introduces the most versatile DualBeam instrument to date. The Versa 3D offers state-of-the-art imaging and analytical performance to deliver a greater range of 3D data from even your most challenging samples.
Loading...
Versa 3D's highly configurable platform allows customers to adapt the system's capabilities to their specific requirements. The high vacuum-only version is ideal for routine conductive or coated samples. An alternative version, combining high and low vacuum modes, gives the flexibility to work with a range of samples including uncoated, non-conductive samples. Optional ESEM mode allows electron beam imaging of uncoated, non-conductive or naturally hydrated samples and supports in situ analysis and dynamic experimentation.

In high vacuum mode, the high current Focused Ion Beam (FIB) enables fast material removal and low voltage clean-up for low-damage surface finishing. Gas chemistries are available for depositing materials or further enhancing the FIB milling rate or selectivity. Nonconductive samples are easily milled with the automated Drift Suppression milling mode which is also supported in the optional AutoSlice and View™ G3 software; for collecting serial slice electron images in both high and low vacuum after high vacuum FIB slicing. Automation can be extended to gather EDS or EBSD data from successive slices. With advanced automation, Versa 3D can acquire images at high vacuum, low voltage and use high or low vacuum for higher voltage imaging and analysis, optimizing conditions for each detector to enhance 3D data segmentation for quantitative 3D reconstruction.

The ultra-large chamber allows addition of a variety of accessories and detectors to support a broad range of imaging and analytical techniques, accessing information from every angle. The new widescreen display provides additional imaging area to view results. New software (SmartSCAN™ and DCFI™) and electronics offer even greater imaging stability for increased performance in all operating modes. Developments in field emission electron source technology ensure clear, sharp electron images as well as increased electron beam current for enhanced EDS, WDS and EBSD analysis.

With Versa 3D the choice is yours to optimize the system for conductive samples in high vacuum; non-conductive samples with low vacuum; or expand the horizons of research to dynamic applications.

Key Benefits
  • DualBeam functionality to examine surface and sub-surface areas of any sample (sample modification at the nm and um scale)
  • Combination of high current FIB cutting/deposition and low voltage FIB cleaning to quickly cut/deposit materials and produce the highest quality, low damage sample surfaces
  • High quality TEM and atom probe sample preparation with low voltage cleaning for atomic level study by TEM/atom probe
  • Full complement of software* to perform advanced tasks like 3D volume slicing for characterization, sample preparation and prototyping from CAD or image files
  • Flexibility of electron beam vacuum configuration for examining conductive samples in high vacuumonly or conductive and non-conductive samples in high and low vacuum configured system
  • Auto Slice and View G3* enables 3D characterization of a wide range of materials types with a suite of detectors* to obtain information from every angle
  • ESEM* option enables dynamic experiments involving gas* and thermal control*
Loading...

 

  Electron
Beam
Ion Beam
Versa 3D (high vacuum-only)

Resolution:
-- 0.8 nm @ 30 kV STEM
-- 1.0 nm @ 30 kV (with Plasma cleaner)
-- 1.2 nm @ 30 kV
-- 1.3 nm @ 15 kV (with Plasma cleaner)
-- 2.0 nm @ 1 kV (with Beam Deceleration)
-- 2.9 nm @ 1 kV
Landing Voltage:
50 V - 30 kV
Probe current:
< = 200 nA
Resolution:
7.0nm @ 30 kV at eucentric
5.0nm @ 30 kV at optimum
Landing Voltage:
500 V - 30 kV
Probe current:
1.5 pA - 65 nA

Versa 3D (high and low vacuum) Resolution ( high vacuum):
-- 0.8 nm @ 30 kV STEM
-- 1.0 nm @ 30 kV SE(with Plasma cleaner)
-- 1.2 nm @ 30 kV SE
-- 1.3 nm @ 15 kV SE(with Plasma cleaner)
-- 2.0 nm @ 1 kV SE (with Beam Deceleration)
-- 2.9 nm @ 1 kV SE
Landing Voltage (high vacuum):
50 V - 30 kV
Probe current:
< = 200 nA
Resolution ( low vacuum):
-- 1.5 nm @ 30 kV SE
-- 2.5 nm @ 30 kV (optional) BSE
-- 3.0 nm @ 3 kV SE
Landing Voltage (low vacuum):
200 V - 30 kV
Resolution (high vacuum-only):
7.0nm @ 30 kV at eucentric
5.0nm @ 30 kV at optimum
Landing Voltage:
500 V - 30 kV
Probe current:
1.5 pA - 65 nA

 

Upgrades & Accessories

1 - 10 of 33
1 2 3 4 

1000 °C Heating Stage

Works With: Quanta 200(FEG), 250(FEG), 400(FEG), 450(FEG), 600(FEG), 650(FEG), Quanta 3D/3D(FEG) and Versa 3D (with ESEM option)
The 1000 °C heating stage is used to heat samples and record in-situ morphological sample changes.

1500 ºC Heating Stage

Works With: Quanta 250(FEG), 450(FEG) and 650(FEG), Quanta 3D FEG and Versa 3D
The 1500 ºC heating stage is the total heating solution to record in-situ morphological sample changes during heating up to 1500 ºC.

6-Channel Detector Amplifier

Works With: Nova NanoSEMx30, Nova NanoLab, Quanta 3D(FEG) family, Versa 3D and Strata 400
Pre-amplifier for all solid-state backscattered detectors such as the low-kV solid state backscattered detector or the 14-segment retractable STEM detector. The design of the pre-amplifier allows TV-rate imaging throughput, even for solid-state backscattered detectors.

Auto FIB

Works With: Versa 3D, V600, Helios, Nova NanoLab, Strata and Quanta 3D (FEG) Series
AutoFIB is a multi-site software automation package for FEI Small DualBeam (SDB) instruments. The package allows for unattended performing of FIB tasks after macro-recording. AutoFIB’s capabilities can be extended by application-specific automation software such as AutoTEM.

Auto TEM

Works With: Versa 3D, V600, Helios, Nova NanoLab, Strata and Quanta 3D (FEG) Series
AutoTEM is automation software for unattended TEM sample preparation by Focused Ion Beam Nano-machining. Throughput typically is two samples per hour depending on the required final thickness of the sample. The AutoTEM option requires Auto FIB, Platinum or Tungsten gas chemistry.

AutoSlice and View

Works With: Versa 3D, V600, Helios, Nova NanoLab, Strata and Quanta 3D (FEG) Series
Automation software for unattended serial sectioning and imaging through a site-specific volume of the specimen. The sequence of images can be merged into a video or be used as the input for 3-dimensional reconstruction of the volume subjected to the slice-and-view process.

Beam Deceleration

Works With: Versa 3D
The Beam Deceleration option enables adjustment of the landing energy of the electron beam on the sample for conductive and partially conductive samples. This option improves low kV aberrations and thus the resolution and contrast can be increased at low kV for many samples.

Carbon Deposition

Works With: Nova NanoSEM, Nova NanoLab, Helios, Strata, Q3D(FEG) Series, V600FIB and Versa 3D
Gas chemistry solution (Naphthalene) for Ion or Electron beam deposition of Carbon-based material, mounted on any of the available GIS ports.

CryoMAT

Works With: Quanta™ 250, 450 and 650; Quanta 200, 400 and 600 (MK2 only); Quanta FEG 250, 450 and 650 • Quanta FEG 200, 400 and 600; Nova™ NanoLab 200, 600 and 600(i); Helios NanoLab™ 600; Quanta 3D 200i; Quanta 3D FEG and Versa 3D
The CryoMAT is a materials-dedicated, cryogenic upgrade to Quick Loader (loadlock system for SEM and DualBeam) and meets the demand for easier and more practical operation than a generic full cryo transfer system.

Delineation Etch

Works With: Nova NanoLab, Strata, Helios Series, Quanta 3D FEG and Versa 3D
Gas chemistry (TFA) solution for decoration of FIB-prepared cross-sections, preferably mounted on GIS port 1.
Contact Sales

More DualBeams:

Loading...

DualBeam™ and FIB capability applied to metals research

Discover the value of FEI DualBeam™ technology when applied to metals research, such as for coatings and stress analysis studied with indentations.

Read the PDF